Preparing for COLA accreditation · by Sound Lab ConsultantsCall (602) 874-1311
COLA Lab Consultantsby Sound Lab ConsultantsBook a consultationBook a call

The COLA accreditation process

Reviewed November 27, 2026 by the Sound Lab Consultants laboratory compliance team
Short answer

COLA accreditation runs in five steps: enroll and receive the COLA Accreditation Manual, complete an optional self-assessment, host the on-site survey, correct any citations after the survey, and receive accreditation. The cycle repeats every two years, and labs must keep meeting the criteria between surveys.

Step by step

  1. Enrollment. Apply to COLA and list your test menu. COLA sends the accreditation manual and an information packet.
  2. Self-assessment. Optional, and worth doing: compare your records against the criteria and fix gaps early.
  3. On-site survey. A surveyor or team reviews records, observes testing and interviews staff. Preliminary findings are shared at the end of the visit.
  4. Post-survey corrective action. Answer each citation with evidence by the date in your report.
  5. Accreditation. Accreditation is granted once corrections are accepted, followed by ongoing compliance and the next survey in two years.

Regulations behind this

RegulationWhat it covers
42 CFR § 493.551General requirements for laboratoriesGeneral requirements for accredited laboratories
42 CFR § 493.1773Standard: Basic inspection requirements for all laboratories issued a CLIA certificate and CLIA-exempt laboratoriesBasic inspection requirements

Full text of the regulations

Tap a regulation to read the complete official text.

§ 493.551 General requirements for laboratories.

(a) Applicability. CMS may deem a laboratory to meet all applicable CLIA program requirements through accreditation by a private nonprofit accreditation program (that is, grant deemed status), or may exempt from CLIA program requirements all State licensed or approved laboratories in a State that has a State licensure program established by law, if the following conditions are met:

(1) The requirements of the accreditation organization or State licensure program are equal to, or more stringent than, the CLIA condition-level requirements specified in this part, and the laboratory would meet the condition-level requirements if it were inspected against these requirements.

(2) The accreditation program or the State licensure program meets the requirements of this subpart and is approved by CMS.

(3) The laboratory authorizes the approved accreditation organization or State licensure program to release to CMS all records and information required and permits inspections as outlined in this part.

(b) Meeting CLIA requirements by accreditation. A laboratory seeking to meet CLIA requirements through accreditation by an approved accreditation organization must do the following:

(1) Obtain a certificate of accreditation as required in subpart D of this part.

(2) Pay the applicable fees as required in subpart F of this part.

(3) Meet the proficiency testing (PT) requirements in subpart H of this part.

(4) Authorize its PT organization to furnish to its accreditation organization the results of the laboratory's participation in an approved PT program for the purpose of monitoring the laboratory's PT and for making the annual PT results, along with explanatory information required to interpret the PT results, available on a reasonable basis, upon request of any person. A laboratory that refuses to authorize release of its PT results is no longer deemed to meet the condition-level requirements and is subject to a full review by CMS, in accordance with subpart Q of this part, and may be subject to the suspension or revocation of its certificate of accreditation under § 493.1840.

(5) Authorize its accreditation organization to release to CMS or a CMS agent the laboratory's PT results that constitute unsuccessful participation in an approved PT program, in accordance with the definition of “unsuccessful participation in an approved PT program,” as specified in § 493.2 of this part, when the laboratory has failed to achieve successful participation in an approved PT program.

(6) Authorize its accreditation organization to release to CMS a notification of the actions taken by the organization as a result of the unsuccessful participation in a PT program within 30 days of the initiation of the action. Based on this notification, CMS may take an adverse action against a laboratory that fails to participate successfully in an approved PT program.

(c) Withdrawal of laboratory accreditation. After an accreditation organization has withdrawn or revoked its accreditation of a laboratory, the laboratory retains its certificate of accreditation for 45 days after the laboratory receives notice of the withdrawal or revocation of the accreditation, or the effective date of any action taken by CMS, whichever is earlier.

Official text from the Electronic Code of Federal Regulations (eCFR), current as of November 24, 2026.

§ 493.1773 Standard: Basic inspection requirements for all laboratories issued a CLIA certificate and CLIA-exempt laboratories.

(a) A laboratory issued a certificate must permit CMS or a CMS agent to conduct an inspection to assess the laboratory's compliance with the requirements of this part. A CLIA-exempt laboratory and a laboratory that requests, or is issued a certificate of accreditation, must permit CMS or a CMS agent to conduct validation and complaint inspections.

(b) General requirements. As part of the inspection process, CMS or a CMS agent may require the laboratory to do the following:

(1) Test samples, including proficiency testing samples, or perform procedures.

(2) Permit interviews of all personnel concerning the laboratory's compliance with the applicable requirements of this part.

(3) Permit laboratory personnel to be observed performing all phases of the total testing process (preanalytic, analytic, and postanalytic).

(4) Permit CMS or a CMS agent access to all areas encompassed under the certificate including, but not limited to, the following:

(i) Specimen procurement and processing areas.

(ii) Storage facilities for specimens, reagents, supplies, records, and reports.

(iii) Testing and reporting areas.

(5) Provide CMS or a CMS agent with copies or exact duplicates of all records and data it requires.

(c) Accessible records and data. A laboratory must have all records and data accessible and retrievable within a reasonable time frame during the course of the inspection.

(d) Requirement to provide information and data. A laboratory must provide, upon request, all information and data needed by CMS or a CMS agent to make a determination of the laboratory's compliance with the applicable requirements of this part.

(e) Reinspection. CMS or a CMS agent may reinspect a laboratory at any time to evaluate the ability of the laboratory to provide accurate and reliable test results.

(f) Complaint inspection. CMS or a CMS agent may conduct an inspection when there are complaints alleging noncompliance with any of the requirements of this part.

(g) Failure to permit an inspection or reinspection. Failure to permit CMS or a CMS agent to conduct an inspection or reinspection results in the suspension or cancellation of the laboratory's participation in Medicare and Medicaid for payment, and suspension or limitation of, or action to revoke the laboratory's CLIA certificate, in accordance with subpart R of this part.

[63 FR 26737, May 14, 1998; 63 FR 32699, June 15, 1998]

Official text from the Electronic Code of Federal Regulations (eCFR), current as of November 24, 2026.

Frequently asked questions

What happens if COLA finds problems?

You receive citations and must submit corrections with evidence by the date in your survey report, then COLA reviews them before accreditation is granted.

More on COLA Lab Consultants

Talk to a lab consultant

Sound Lab Consultants helps labs in all 50 states with CLIA certificates, accreditation, lab startup, director and technical consultant roles, and survey citations, remote and on-site.

Book a free consultationVisit soundlabconsult.com